Common causes of data export failure - HxGN SDx - Update 63 - Administration & Configuration

Administration and Configuration of HxGN SDx

Language
English
Product
HxGN SDx
Search by Category
Administration & Configuration
SmartPlant Foundation / SDx Version
10

Document revision

Problem

The later revision (by issue date) does not have the higher revision code.

Solution

  • Revisions are sequenced by their issue date time stamp.

    • The issue date time stamp is the date entered in the Issue Date column appended by the current time on the server to enable the loading of more than one revision on any day.

    • To create a new revision of a document.

      • The revision of the loaded document must be higher in the revision sequence than on the CURRENT revision in the system.

      • The issue date of the loaded document must be later than on the CURRENT revision in the system.

  • If the issue date of the loaded document is earlier than on the CURRENT revision in the system, it will assume that the load is intended to create a historical revision in which case, its revision must also be lower in the revision sequence than on the CURRENT revision.

It is not possible to insert a historical revision directly behind a working revision of an existing document.

Issue date validation

Problem

Issue date cannot be in the future.

Solution

The issue date of a document revision cannot be a future date.

The planned issue date on the planning submittals can be a future date.