Error message

"The HTTP request is unauthorized with client authentication scheme ‘Anonymous’. The authentication header received from the server was 'Negotiate,NTLM'".

Problem

Upon running a job, Data Validator fails to import data into the staging area if Windows authentication is enabled.

Solution

Configure the target system to use the net.tcp protocol instead of the http protocol. For example, when creating a target system in the Create New Target System dialog box in Data Validator Administration, type the target system URL in the Target System URL text box as net.tcp://[Target System Name]/[Target Site Name]Server.

Net.tcp has improved performance features if the usage is within the firewall on the same network. It is recommended that users use this protocol.