Equipment menu: Utilities > Nozzle Schedule > Total
Equipment menu: Utilities > Nozzle Schedule > Single
Command line: NSCHTOTAL
Command line: NSCHSINGLE
Generates the main nozzle schedule. The NSCHTOTAL option provides one tag for all nozzle components with similar parametric parameters.
If no nozzle components are detected or selected, the generator stops.
Counter
Starts the tag counter from any positive non-zero integer. After the counter is set, the command prompts you to pick Manual or Automatic placement of tags.
Manual placement
Inserts tags manually. The software prompts you for the location of the tag and displays a rubber band line attached to the component extending to the tag location. The process continues until the last component’s tag has been placed.
Automatic placement
Inserts tags automatically. In model space, the software places the tag in the direction (tag to component) provided at the prompt. In paper space, the placement angle prompt does not display. If you are in paper space, the nozzle schedule generator switches to the last model view for component selection.
What do you want to do?