Click (+) on the Data Tables folder in Catalog Data.
The Data Tables folder expands displaying the categories or groups depending on your view selection.
-
Select Gaskets\Bolts\Welds.
If you set your Data Table List Mode in the View tab to Group List Mode, then you must right-click Gaskets/Bolts/Welds, and then select Add Data Table. You can then continue to step 5.
-
Click (+) on the Gaskets\Bolts\Welds folder.
The folder expands, displaying the data tables.
-
Select Bolts, right-click, and then select Add Data Table.
The New Data Table dialog box displays with defaults for Name, Category, Type, BOM Type, and Color Index.
-
Type a Name.
If you set your Data Table List Mode in the View tab to Group List Mode, then you must select a Category, and Type after typing a name.
-
Select a Size Table.
-
Click the Size Table ellipsis , select the sizes to add from the Select Size list, and then click OK.
Use the Select / deselect all check box to select or clear all sizes.
-
Type a Part Number.
-
Type the Selection Code for the bolt.
-
Update the BOM Type list if needed.
-
Select a Layer Name.
-
Update the Color Index list if needed.
-
Type the Sort Sequence.
-
Type the Isogen Identifier.
-
Select an Isogen SKEY.
-
Select whether or not the component is an optional component, by selecting the Optional Component check box.
-
Type the Description for the table.
-
Click OK.
The new data table displays in the Main Table List View and in Catalog Data.